Research
G303: Measuring Boiler Tube Wall Thickness in Thermal Power Plants Using Electromagnetic Acoustic Transducers
The objective set for this work was to design an electromagnetic acoustic transducer (EMAT) for in-situ measurement of boiler tube wall thickness, in power station heat-exchangers, where the presence of scale on the tube precludes the use of piezoelectric transducers.Stage I of the project covered the design criteria for the electromagnetic acoustic transducer (EMAT) and the instrumentation required to collect and process the data. This report covers Stage II of the project but includes also a s
Jul 1, 1982 - Sep 1, 1984